Analyte: Glucagon, Proglucagon
Regulatory status: For Research Use Only. Not for use in diagnostic or therapeutic procedures.
Packaging: 96 well microtiter
Dynamic range: 6, 6.48 - 913 pg/mL
Limit of detection: 1.14 pg/mL
Sample size: 25 µL
Sample type: Plasma
Assay time: 2.5 hours
Shelf life: 24 months
Availability: Worldwide
Analyte: Proglucagon
Regulatory status: For Research Use Only. Not for use in diagnostic or therapeutic procedures.
Packaging: 96 well microtiter
Dynamic range: 6, 0.05-3 ng/mL
Limit of detection: 0.003 ng/mL
Sample size: 25 µL
Sample type: Plasma
Assay time: 2.5 hours
Shelf life: 24 months
Availability: Worldwide
Analyte: Glicentin
Regulatory status: For Research Use Only. Not for use in diagnostic or therapeutic procedures.
Packaging: 96 well microtiter
Dynamic range: 6, 33.3-1666 pg/mL
Limit of detection: 4.17 pg/mL
Sample size: 25 µL
Sample type: Plasma
Assay time: 2.5 hours
Shelf life: 24 months
Availability: Worldwide
Analyte: Oxyntomodulin
Inventory status: Made to order. Inquire about leadtime.
Regulatory status: For Research Use Only. Not for use in diagnostic or therapeutic procedures.
Packaging: 96 well microtiter
Dynamic range: 6, 11.4-859 pg/mL
Limit of detection: 2.55 pg/mL
Sample size: 10 µL
Sample type: Plasma
Assay time: 2 hours
Shelf life: 24 months
Availability: Worldwide
Analyte: GLP-2
Regulatory status: For Research Use Only. Not for use in diagnostic or therapeutic procedures.
Packaging: 96 well microtiter
Dynamic range: 6, 0.14-7.5 ng/mL
Limit of detection: 0.011 ng/mL
Sample size: 50 µL
Sample type: Plasma
Assay time: 2.5 hours
Shelf life: 24 months
Availability: Worldwide
Analyte: GLP-1
Regulatory status: For Research Use Only. Not for use in diagnostic or therapeutic procedures.
Packaging: 96 well microtiter
Dynamic range: 6, 15-213 pg/mL
Limit of detection: 1.9 pg/mL
Sample size: 50 µL
Sample type: Plasma
Assay time: 2.5 hours
Shelf life: 24 months
Availability: Worldwide
Analyte: Glucagon
Regulatory status: For in vitro diagnostic use.
Packaging: 96 well microtiter
Dynamic range: 6, 7-314 pg/mL
Limit of detection: 2.4 pg/mL
Sample size: 50 µL
Sample type: Plasma
Assay time: 2.5 hours
Shelf life: 24 months
Availability: Worldwide
Analyte: Oxyntomodulin
Regulatory status: For Research Use Only. Not for use in diagnostic or therapeutic procedures.
Packaging: 96 well microtiter
Dynamic range: 6, 3-290 pg/mL
Limit of detection: 0.243 pg/mL
Sample size: 50 µL
Sample type: Plasma
Assay time: 2 hours
Shelf life: 24 months
Availability: Worldwide