AMH, Bovine

Bovine AMH Test Kit – CLIA
Bovine AMH Test Kit – ELISA

Pic

Description:
Bovine Anti-Mullerian Hormone (AMH) Test Kit
Catalog number: AnshLite™ Bovine AMH CLIA, AL-214
Kit / type: 96-well (12×8 removable strips) microtiter plate CLIA
Detection: HRP-based enhanced chemiluminescence, utilizing our proprietary AnshLite™ luminogenic substrate
Intended use: Unless otherwise stated in our catalog or other company documentation accompanying Ansh Labs product(s), the products are intended for research use only, and not for in vitro diagnostic purposes, or therapeutic uses of any type involving consumption or application to humans or animals.
Assay note(s): Quantitative three-step sandwich type immunoassay. Total 3.5 hour incubation time at room temperature.
Sample type(s): Serum, Plasma
Sample size: 50 μL
Analytical Specificity:
Species reactivity: Bovine
Calibration range: 7 points = 0, 0.156-10 ng/mL
Recovery (accuracy):
Linearity of dilution:
Limit of quantitation: 0.1 ng/mL
Limit of detection:
Intra-assay %CV:
Inter-assay %CV:
Stability: 24 months from manufacture date
Storage: IMPORTANT: Store Calibrators at -20°C or colder upon receipt. Store remaining reagents at 2-8°C.
Downloads: IFU
Description:
Bovine Anti-Mullerian Hormone (AMH) Test Kit
Catalog number: Bovine AMH ELISA, AL-114
Kit / type: 96-well (12×8 removable strips) microtiter plate ELISA
Detection: HRP-based ELISA, colorimetric detection by dual wavelength absorbance at 450 nm and 630 nm as reference filter
Intended use: Unless otherwise stated in our catalog or other company documentation accompanying Ansh Labs product(s), the products are intended for research use only, and not for in vitro diagnostic purposes, or therapeutic uses of any type involving consumption or application to humans or animals.
Assay note(s): Quantitative three-step sandwich type immunoassay. Total 3.5 hour incubation time at room temperature.
Sample type(s): Serum, Plasma
Sample size: 50 μL
Analytical Specificity:
Species reactivity: Bovine
Calibration range: 7 points = 0, 0.156-10 ng/mL
Recovery (accuracy):
Linearity of dilution:
Limit of quantitation: 0.11 ng/mL
Limit of detection:
Intra-assay %CV:
Inter-assay %CV:
Stability: 18 months from manufacture date
Storage: IMPORTANT: Store Calibrators at -20°C or colder upon receipt. Store remaining reagents at 2-8°C.
Downloads: IFU
Description:
Bovine Anti-Mullerian Hormone (AMH) Test Kit
Catalog number: AnshLite™ Bovine AMH CLIA, AL-214
Kit / types: 96-well (12×8 removable strips) microtiter plate CLIA
Detection: HRP-based enhanced chemiluminescence, utilizing our proprietary AnshLite™ luminogenic substrate
Intended use: Unless otherwise stated in our catalog or other company documentation accompanying Ansh Labs product(s), the products are intended for research use only, and not for in vitro diagnostic purposes, or therapeutic uses of any type involving consumption or application to humans or animals.
Assay note(s): Quantitative three-step sandwich type immunoassay. Total 3.5 hour incubation time at room temperature.
Sample type(s): Serum, Plasma
Sample size: 50 μL
Analytical Specificity:
Species reactivity: Bovine
Calibration range: 7 points = 0, 0.156-10 ng/mL
Recovery (accuracy):
Linearity of dilution:
Limit of quantitation: 0.1 ng/mL
Limit of detection:
Intra-assay %CV:
Inter-assay %CV:
Stability: 24 months from manufacture date
Storage: IMPORTANT: Store Calibrators at -20°C or colder upon receipt. Store remaining reagents at 2-8°C.
Downloads: IFU
Description:
Bovine Anti-Mullerian Hormone (AMH) Test Kit
Catalog number: Bovine AMH ELISA, AL-114
Kit / types: 96-well (12×8 removable strips) microtiter plate ELISA
Detection: HRP-based ELISA, colorimetric detection by dual wavelength absorbance at 450 nm and 630 nm as reference filter
Intended use: Unless otherwise stated in our catalog or other company documentation accompanying Ansh Labs product(s), the products are intended for research use only, and not for in vitro diagnostic purposes, or therapeutic uses of any type involving consumption or application to humans or animals.
Assay note(s): Quantitative three-step sandwich type immunoassay. Total 3.5 hour incubation time at room temperature.
Sample type(s): Serum, Plasma
Sample size: 50 μL
Analytical Specificity:
Species reactivity: Bovine
Calibration range: 7 points = 0, 0.156-10 ng/mL
Recovery (accuracy):
Linearity of dilution:
Limit of quantitation: 0.11 ng/mL
Limit of detection:
Intra-assay %CV: 2.0%
Inter-assay %CV: 0.6%
Stability: 18 months from manufacture date
Storage: IMPORTANT: Store Calibrators at -20°C or colder upon receipt. Store remaining reagents at 2-8°C.
Downloads: IFU